Building Code Exterior Door Landing

Where a door opens over a landing the landing shall be at least as wide as the door and at least 5 feet long.
Building code exterior door landing. 4 a landing may be omitted at the bottom of an exterior stair or ramp provided there is no obstruction such as a gate or door within the lesser of the width of the stair or ramp or. Aisle stairs complying with section 1025 11. For all non egress exterior doors the 2003 code update allows a 7 3 4 in. This handout is intended to provide only general information contact the building and safety division for any questions or additional information.
R311 3 floors and landings at exterior doors there shall be a landing or floor on each side of. Building codes for exterior doors. 3 1 sentence 3 does not apply to an exterior stair serving a secondary entrance to a house that is also a main entrance to a dwelling unit in the house. When fully open the door shall not project more than 7 inches 178 mm into a landing.
Defects in masonry steps and landings outdoors sketches of exterior stair design requirements questions answers about exterior stair code specifications. Florida building code 1009 4 stairway landings. Step down on the interior and up to two steps down to the landing on the exterior regardless of which way the door swings it can only swing over one step. The landing or floor on the exterior side shall be not more than 7 3 4 inches 196 mm below the top of the threshold provided the door does not swing over the landing or floor.
Where exterior landings or floors serving the required egress door are not at grade they shall be provided with access to grade by means of a ramp in. The landing or floor on the exterior side shall be not more than 7 3 4 inches 196 mm below the top of the threshold provided the door does not swing over the landing or floor. The massachusetts state building code consists of a series of international model codes and any state specific amendments adopted by the board of building regulation and standards bbrs. Doors opening onto a landing shall not reduce the landing to less than one half the required width.
Landing requirements for all other exterior doors. This allowance provides some design flexibility. Title 24 part 2 section 2 3303 i 1 and i 2 exception. Where exterior landings or floors serving the required egress door are not at grade they shall be provided with access to grade by means of a ramp in.
Exterior doors in homes and businesses not only provide security but they also serve as a vital means of egress during a fire or other emergency. Florida building code 1009 4 stairway.