Cable Tray Sizing Formula

Chart is based on 50 fill of 4 utp category 6 cable o d 21 033lbs ft not maximum loading weight for the tray.
Cable tray sizing formula. Straight section supports installed at 5 foot 1 5m centers are typical. Derating factors will be available in cable catalog. Total diameter of all cables laying in tray 340 6mm. Diameter of 25sq mm cable no of cable x outer diameter of each cable.
Mm x 4 62 77 sq. Per nec tray sizing instructions 1 insure that macros have been enabled. Practical guide on the amount of cable weight that can be installed tested in accordance with nema ve 1 csa e222 2 126 1. Cable tray is sized based on the number and type of cables required for the current and future need.
Generally cable tray sizing is correct when it appears 50 full of cable or wire or when it contains a 50 fill of cables or wire. The installation will use cat cable at 19 in diameter 20 lb. Number of cable per trench is 1 number of run of cable is 1 run. An example how to calculate voltage drop and size of electrical cable photo credit.
Get the cable size corresponding to this derated current from the catalog. Tray design depth sum of od in total cross sectional areas of all cables. 3 use the pull down menu to choose the type of cables being used and answer any of the pop up questions. An 8awg thhn wire has a cross section of 23 61 square mm 0 03659 square in a 4 awg thw has a cross section of 62 77 square mm 0 09729 square in therefore the wires total cross sectional area is.
Calculate cable tray width calculate cable tray area calculate cable tray length calculate cable tray weight calculate remaining width of cable tray calculate remaining area of cable tray free download. Quick tray wire mesh cable tray fill table at 50 fill use the following formula to calculate the number of cables that will result in a particular fill ratio where. On tue dec 2 2014 at 7 52 pm electrical notes articles wrote. Total sum of the diameters.
Total diameter of all cables laying in tray 119 4 137 2 54 mm. Cable raceway tray support calculations. I load in kw sqrt 3 v in kv p f a the current obtained has to derated since the cable is designed to operate at a defined temperature. Cable trays may be filled 50 when using control or signal wiring.
Mm x 2 219 98 sq. Diameter of 400sq mm cable 2x68 6 137 2 mm. A inside tray area in in 2 d cable diameter in inches f fill ratio in n number of cables the formula is n f a 100 d 2 2 π example. A 50 fill ratio should equal the maximum number of cables pulled in a given cross section.
The cable tray sizing equals the width times the loading depth. The sum of the cross sectional areas of all cables cannot exceed 50 of the trays fill area.